Tracking Resistance Erosion Test Equipment is used for checking the relative behavior of solid electrical insulating material with regard to their susceptibility to surface tracking when exposed under electric stresses, to water and contaminants, from the surroundings.

The grading of materials arrived at by checking the tracking index may possibly differ from that obtained by utilizing other checking methods for the measurements of the tracking index.

The results obtained by checking tracking index are not used directly for evaluation of safe creepage distances while designing any electrical apparatus.

With this apparatus drops of an electrolyte are dropped at defined time interval to the surface of insulating materials between two electrodes to which a voltage is applied.

The number of drops at which break down occurs across the surface is the function of voltage

The numerical values of the voltage corresponding to the asymptotes defines the tracking resistance.The value of voltage corresponding to number of drops is taken as the comparative index. (This test should be done as fast as possible)

The number of drops to cause tracking at value of predetermined test voltage 10% below the number of drops value is indicated as the degree to which the reported  comparative tracking

Request Quote

Impulse Generator

Impulse Generator, Impulse Voltage test systems

Description

‘RE’ Impulse Generators operates under a control system, which charges the impulse generator by the  charging unit. Charging time and charging voltage can be selected. Once the selected charging voltage has been reached, a trigger pulse initiates the firing of the lowest spark-gap of the impulse generator. When all the spark-gaps fired all the stages are connected in series thus multiplying the charging voltage. The impulse voltage divider reduces he impulse voltage to a value that the measuring and recording instruments require.

Request Quote

Download Catalogue

 Kilo Volt Meters / Voltage Dividers

Description

Description

Kilo Volt Meter (kV) meters  used tomeasure the kilo volt value of an Instrument Transformer, CT/PT etc. The unit is used for higher value calibration with a wide range from 1% to 110%. Kilo Voltmeters are highly accurate, portable voltage measurement systems traceable to NABL standards. The Kilo meter series consists of a high voltage divider assembly, a precision readout device and interconnection leads. The battery operation makes the system completely portable for field testing while the precision divider assembly and readout device makes it suitable for laboratory use.

Request Quote

Sphere Gaps

Description

RE, Sphere Gap is provided with Motorised arrangement to adjust the gap. The lower sphere gap shall Motorised and shall move upwards and downwards for the adjustment of gap. The upper sphere shall be hang shall be roof of the test lab with in insulator and current limiting resistance shall be provided.

Request Quote

Cable Fault Burning Unit

Description

Converts high resistance faults to short circuit fauts. Available for HV/LV cables. For manufactures use only. Helps save the damaged part.

Request Quote

How to reach?

  • Address :
    10/3, DLF Industrial Area, Moti Nagar, New Delhi - 110015
  • Tel : +91 - 11 -  4368 0100
  • Fax : +91 - 11 - 41425853 
  • Email Id : This email address is being protected from spambots. You need JavaScript enabled to view it.
  • Website : www.re-india.com

Quick Contact

Powered by ChronoForms - ChronoEngine.com