+91-8800390502         info@re-india.com              Office Location

Sphere Gaps

Description

RE, Sphere Gap is provided with Motorised arrangement to adjust the gap. The lower sphere gap shall Motorised and shall move upwards and downwards for the adjustment of gap. The upper sphere shall be hang shall be roof of the test lab with in insulator and current limiting resistance shall be provided.

Request Quote

Variable Auto Transformers

Description

Description

‘RE’ VARITX is the trade name of the continuously variable voltage Auto transformer manufactured by ‘RE’. It is an most economical effective device for step less and continuous voltage control of Single Phase and 3 phase AC voltages for numerous applications for the industrial and Laboratories usages for testing and calibration purposes.  ‘RE’ VARITX are used for operation at nominal voltage of 240V AC to give output Voltages between 0 to 270V at 50/60 Hz by a Booster Auto Transformer. Three such ‘RE’ VARITX connected electrically in star and mechanically interlocked to move together are used for operation on 415 Volts, 3 phase AC supply to give output from voltage from 0 to 470 Volt at 50/60Hz. ‘RE’ Manufactured VARITX is having good Regulation with Negligible waveform distortion. Varitx are robust, energy efficient, noiseless and easy to operate with excellent short time over load capabilities. ‘RE’ manufacturers specialized Oil cooled or air cooled motorized/manually operated VARITX upto 800 Amps with supply voltage of 240 Volts to give output voltages from 0 to 350 Volts, 3 Phase VARITX up to 800Amps with input supply voltage of 415 Volt 3 Phase to give output Voltages from 0 to 600V.

Request Quote

Inductive Load Bank

Description

Description

Load Banks are designed for load test to be carried on Single/Three Phase AC/ DC Power Supplies, DG sets, UPS and Inverters etc. We manufacture loads up to 3000kW suitable for working on Single Phase 230V +5% and 3Phase  400 V +5%  50HzAC supply. The power factor in AC can be variable/adjustable from 0.2 lag to unity to 0.3 lead. The capacities are available from 5kW to 3000kW. The units are available with Stepped & Stepless versions with Manual, Semi Automatic and Fully Automatic Controllers. Digital Multi function meters are also available to indicate voltage, current, watt, KVAr, Pf.

The Loads are normally designed for continuous operation and are forced air-cooled with auxiliary supply with Independent Controls.

We manufacture following types of Loads:

  • Resistive Loads.
  • Inductive Loads.
  • Capacitive Loads.
  • Resistive/Inductive combined Loads.
  • Resistive/Inductive/Capacitive combined Loads.

Each load banks consist of coarse and fine controls as per the specific requirements.

Request Quote

Resistive Load Bank

Description

Description

Load Banks are designed for load test to be carried on Single/Three Phase AC/ DC Power Supplies, DG sets, UPS and Inverters etc. We manufacture loads up to 3000kW suitable for working on Single Phase 230V +5% and 3Phase  400 V +5%  50HzAC supply. The power factor in AC can be variable/adjustable from 0.2 lag to unity to 0.3 lead. The capacities are available from 5kW to 3000kW. The units are available with Stepped & Stepless versions with Manual, Semi Automatic and Fully Automatic Controllers. Digital Multi function meters are also available to indicate voltage, current, watt, KVAr, Pf.

The Loads are normally designed for continuous operation and are forced air-cooled with auxiliary supply with Independent Controls.

We manufacture following types of Loads:

  • Resistive Loads.
  • Inductive Loads.
  • Capacitive Loads.
  • Resistive/Inductive combined Loads.
  • Resistive/Inductive/Capacitive combined Loads.

Each load banks consist of coarse and fine controls as per the specific requirements.

Request Quote

 

Inductive & Resistive Load Bank

Description

Description

Load Banks are designed for load test to be carried on Single/Three Phase AC/ DC Power Supplies, DG sets, UPS and Inverters etc. We manufacture loads up to 3000kW suitable for working on Single Phase 230V +5% and 3Phase  400 V +5%  50HzAC supply. The power factor in AC can be variable/adjustable from 0.2 lag to unity to 0.3 lead. The capacities are available from 5kW to 3000kW. The units are available with Stepped & Stepless versions with Manual, Semi Automatic and Fully Automatic Controllers. Digital Multi function meters are also available to indicate voltage, current, watt, KVAr, Pf.

The Loads are normally designed for continuous operation and are forced air-cooled with auxiliary supply with Independent Controls.

We manufacture following types of Loads:

  • Resistive Loads.
  • Inductive Loads.
  • Capacitive Loads.
  • Resistive/Inductive combined Loads.
  • Resistive/Inductive/Capacitive combined Loads.

Each load banks consist of coarse and fine controls as per the specific requirements.

Request Quote

How to reach?

  • Address :
    10/3, DLF Industrial Area, Moti Nagar, New Delhi - 110015
  • Tel : +91 - 11 -  4368 0100
  • Fax : +91 - 11 - 41425853 
  • Email Id : This email address is being protected from spambots. You need JavaScript enabled to view it.
  • Website : www.re-india.com

Quick Contact

Powered by ChronoForms - ChronoEngine.com